Home page

 

If you are looking for the supplier of solar water heaters, or if you are about to set foot in the business of renewable energy, then you come to the right place! GREENMASTER Ltd, one of the best suppliers of solar water heaters in China, will provide you various excellent products and the most professional service. If you are interested in the systems showed below, please don't hesitate to mail us: sales@greenmasterinc.com

 

No. Content
I Solar Keymark Certified Solar Water Heater Systems
II Flat Plate Solar Water Heaters
III Intelligent Controllers of Solar Water Heaters
IV Solar Workstations (pump & controller)
V Pump Stations

 

Part I: Solar Keymark Certified Solar Water Heater Systems

Kinds of system

Pressurized Solar Water Heater Separated from Water Tank

Pressurized Solar Water Heater Integrated with Water Tank

Non­-pressurized Solar Water Heater Integrated with Water Tank

Photos

Application

Most condition of family usage

The house or apartment that has enough place on the roof for the installation

The house or apartment that is high enough to drive the water from the roof to the bathroom

Key Advantage

Continuously provide hot water, flexible installation and aesthetic appearance

Continuously provide hot water

Easy installation and attractive price

Warranty

15 years for heat pipes

3 years for the copper pipe in the manifold box

10 years for the separated tank, 3 years for the integrated tank

Relevant Downloads: IOM manual of solar water heater

Go top

 

 

 

Part II: Flat Plate Solar Water Heater 

 

 

Part III: Intelligent Controllers of Solar Water Heater

 

Model

530C6

868C6

718C

618C1

Photos

 

 

 

FOB Shanghai

53 Euro

55 Euro

72 Euro

80 Euro

Mode

Display integrated with control unit

Display separated from control unit

Display integrated with control unit

Display integrated with control unit

Application

single collector array, single tank, single pump

single collector array, single tank, single pump 

1. single collector array, single tank                       2. single collector array, double tanks                    3. single collector array, single tank and solid fuel boiler                               4. single collector array, single tank and heating return pipe                       5. single collector array, single tank and valve controlled swimming pool  6. single collector array, single tank and pump controlled swimming pool

1. single collector array, single tank, single pump                       2. single collector array, double tanks, double pumps                 3. single collector array, double tanks, single pump, single valve                                        4. double collector arrays, single tank, double pumps                     5. double collector arrays, single tank, single pump, single valve     6. double valve-controlled collector arrays, double tanks, single pump, double valves        7. double valve-controlled collector arrays, double tanks, double pumps, single valve        8. double pump-controlled collector arrays, double tanks, double pumps, single valve

Inputs

4 temperature sensors (1 Pt1000 sensor for collector, 2 NTC10K, B3950 sensors for tank bottom & top, 1 NTC10K, B3950 sensor for  hot water circulation pump)

4 temperature sensors (1 Pt1000 sensor for collector, 2 NTC10K, B3950 sensors for tank bottom & top, 1 NTC10K, B3950 sensor for  hot water circulation pump), 1 input (3-wire) for display

5 temperature sensors (1 Pt1000  sensor for collector, 4 NTC10K B3950 sensors for tank)

6 temperature sensors (2 Pt1000 sensors for collector, 4 NTC10K B3950 sensors for tank)

Outputs

4 electromagnetic relays (2*5A for two circulation pumps, 1*16A for electric booster, 1*16A for valve)

3 electromagnetic relays (2*5A for two circulation pumps, 1*16A for electric booster)

* 1 RMP outlet relay (3A) for pump of solar circuit     * 3 electromagnetic relays (1*5A for circulation pump, 1*5A for 3-way electromagnetic valve or circulation pump, 1*16A for electric booster)

5 electromagnetic relays (2*3A for circulation pumps, 2*5A for 3-way electromagnetic valves or circulation pumps, 1*16A for electric booster)

Functions

1. Temperature & time controlled auxiliary heating.      2. Temperature & time controlled hot water circulation.      3. Anti-freezing protection on collector.                 4. High temperature protection on tank.

1. Temperature & time controlled auxiliary heating.        2.Temperature & time controlled hot water circulation.      3.Anti-freezing protection on collector.                  4.High temperature protection on tank.

1. Temperature & time controlled auxiliary heating.        2.Temperature & time controlled hot water circulation.                       3. Anti-freezing protection on collector.                     4. High & low temperature protection on collector.      5. High temperature protection on tank.           6. Circulation pump speed control

1. Temperature & time controlled auxiliary heating.                         2. Temperature & time controlled hot water circulation.                   3. Anti-freezing protection on collector.                                     4. High & low temperature protection on collector.             5. High temperature protection on tank.                                      6. Circulation pump speed adjustment.

Downloads

IOM_530C6

IOM_868C6

IOM_718C

IOM_618C1

Equivalent to RESOL

DeltaSol BS/4

DeltaSol BS/3

DeltaSol BS Plus

DeltaSol ES

RESOL reference price (Euro)

157.2

153.6

207

242.4

Go top

 

Part IV: Solar Workstation (pump & controller)

Economically Attractive & Technically Simple!

Most residential solar water heater installations still required significant installation costs and lacked uniformity and quality control of application. Our Plug & Play Solar Heating Modules are easy to install, durable, and of superior design quality.

Relevant Downloads: 2008 Solar Workstation Catalogue, User’s manual

For installers: Do 70% more installations with no mistakes and no call backs

Reduce Costs:

l         Saves substantial labour time and training costs

l         Pre-tested for reliability and operation

l         Reduced liability – extended warranty available

l         Reduces “parasitic” costs associated with trips back to the wholesaler for necessary items

Increased Revenue:

l         Complete more projects on time and on budget

l         Fixed, measurable costs ensure that projects are quoted profitably and accurately

l         Simple installation requires less time and money for skilled employees

l         Professional trouble-free installations build customer confidence

For wholesalers: Reduce time spent on ordering and stocking, trips to the job site, and more

l         Packaged system purchase - efficient ordering and stocking

l         Single supplier – focused responsibility with a toll free technical support

l         Reduces costly visits to job site to help Contractor troubleshoot problem systems – esp. wiring issues

l         Reduces design time – allowing the wholesaler to quote a great number of projects

 

SPC22623/22823 (Double Pipeline)

 

1.       Heat transfer medium inlet

2.       Display and control panel

3.       Pump speed adjustment switch

4.       Temperature difference circulation pump

5.       Expansion connection

6.       Display screen of flux and temperature

7.       Manometer

8.       Relieve air valve

9.       Safety valve

10.   Steel wall mounting

11.   Flow trip connection

12.   Return trip connection

Components

 

l         Pressure relief valve: 6 bar/ 87 psi.

l         All medium-bearing parts are made of brassl

l         With solar circulation pump (three-level adjustment) by Wilo without wire

l         High-temperature & aseismatic manomete with with a range from 0~10 bar/0~ 150 psi.

l         Flat sealing connection for expansion tank

l         Flow meter: flow quantity measuring device with adjustable flow quantity gauge and function control device

l         Air-Scoop in the supply line for a permanent of the heat transfer medium

l         Pipeline temperature display

l         Medium inletturning the handle 90° to left so that medium can be injected in it.

l         Function-optimized design insulation made of durable elastic EPS; 100% insulation of the fittings -excellent pump ventilation and cooling

l         Screw thread1/2inch

Technical Specification

 

l         Dimension: 450mm*310mm*150mm

l         Range of temperature measuring: 0~150

l         Power of controlled pump (temperature difference circulation pump, water-using end circulation pump): 600W

l         Electrical booster power: ≤3000W

l         SPC22623 - input signal: 3 temperature sensors (for top of tank, for heat collector, for bottom of tank), SPC22823 - 6 temperature sensors (PT1000 for heat collector, NTC 10k B=3950 for water tank)

l         SPC22623- output signal: 3 (electronic booster, temperature difference circulation pump and water-using end circulation pump), SPC22823 - 5 (electronic booster, 4 pumps or 3 pumps and 1 three way electromagnetic valve)

l         System working pressure 8 bar and safety valve response pressure 6 bar

l         Maximum working temperature of pipelineflow trip (manometer side) 150, return trip (pump side) 110

Installation Guide

 

Vertically installed at the flow and return trip between collections and water tank, as below picture.

 

SP11623/11823 (single pipeline)

 

1.       Operating screen

2.       Manometer

3.       Pump speed adjustment switches

4.       Temperature difference circulation pump

5.       Flow rate indicator

6.       Return circuit connection

7.       Safety valve

8.       Expansion vessel connection

9.       Return circuit connection

10.   Wall mounting

Components

 

l         Pressure relief valve: 6 bar/ 87 psi.

l         All medium-bearing parts are made of brassl

l         With solar circulation pump (three-level adjustment) by Wilo without wire

l         High-temperature & aseismatic manomete with with a range from 0~10 bar/0~ 150 psi.

l         Flat sealing connection for expansion tank

l         Flow meter: flow quantity measuring device with adjustable flow quantity gauge and function control device

l         Air-Scoop in the supply line for a permanent of the heat transfer medium

l         Pipeline temperature display

l         Function-optimized design insulation made of durable elastic EPS; 100% insulation of the fittings -excellent pump ventilation and cooling

l         Screw thread1/2inch

Technical Specification

 

l         Dimension: 450mm*310mm*150mm

l         Range of temperature measuring: 0~150

l         Power of controlled pump (temperature difference circulation pump, water-using end circulation pump): 600W

l         Electrical booster power: ≤3000W

l         SPC11623 - input signal: 3 temperature sensors (for top of tank, for heat collector, for bottom of tank), SPC11823 - 6 temperature sensors (PT1000 for heat collector, NTC 10k B=3950 for water tank)

l         SPC11623- output signal: 3 (electronic booster, temperature difference circulation pump and water-using end circulation pump), SPC11823 - 5 (electronic booster, 4 pumps or 3 pumps and 1 three way electromagnetic valve)

l         System working pressure 8 bar and safety valve response pressure 6 bar

l         Maximum working temperature of pipelineflow trip (manometer side) 150, return trip (pump side) 110

Installation Guide

 

Vertically installedinstalled at return trip between collector and water tank. As below picture.

Part V: Pump Station for Solar Water Heaters

 

FAQ

Contact us

 

Go top